Stretchable, flexible dry electrode with quality data
ElecSil™ is a conductive, stretchable smart e-textile for next-generation smart textile technology and bio-interactive electrodes.
Key characteristics
Skin-contact conductivity. No gel. No compromise.
ElecSil™ is a next-generation conductive silicone material engineered for soft, flexible, and skin-safe electrode applications. Developed by Wave Company, ElecSil™ integrates biocompatibility, stretchability, and stable conductivity, making it ideal for wearable devices that move naturally with the body. From EMG garments to rehabilitation systems, ElecSil™ delivers consistent signal quality without sacrificing comfort.
Performance under stretch. Even after more than 100 stretch cycles at 20% strain, ElecSil™ maintains stable electrical resistance. This durability makes it ideal for EMG wearables, rehabilitation suits, fitness garments, and other applications requiring reliable movement-responsive electrodes.

3-layer smart electrode structure
All commercial products are ElecSil™ A+B integrated textile electrodes, printed directly onto stretchable fabric.
ElecSil™ B – skin-contact layer (black). Soft silicone infused with carbon black provides gentle adhesion without irritation.
ElecSil™ A – conductive core (beige). Silver- and copper-infused silicone rubber (PDMS) delivers high conductivity and signal stability.
Fabric layer (spandex). Adds stretch, structural support, and seamless integration into garments and wearable devices.

How conductivity works
When connected to an external stimulation device through snap ports, ElecSil™ delivers electrical signals to targeted muscle areas for activation, recovery, or measurement. It is designed to integrate seamlessly into wearable garments for EMS, EMG, and rehabilitation technologies.

Biocompatible, adhesive-free wearability
ElecSil™ is engineered with user safety in mind. It meets ISO 10993-5 and 10993-10 biocompatibility standards, ensuring it is non-irritating, non-sensitizing, and suitable for long-term skin contact.
Unlike hydrogel electrodes, ElecSil™ contains no sticky adhesives. Users experience a clean, gentle grip on the skin without discomfort: no residue, no irritation, no degradation over time.
Use cases
Where ElecSil™ works

ECG
Skin-conformable electrodes for continuous heart rate and cardiac rhythm monitoring in wearable health devices.

EMG
Capture accurate muscle activity signals for motion analysis, rehabilitation monitoring, and sports science research. Reduced noise compared to disposable electrodes.

EMS (electrical muscle stimulation)
Integrate into compression garments for muscle recovery, physical therapy, and athletic training. ElecSil™ delivers smooth, even stimulation across the electrode surface.

Haptic feedback
Electrotactile stimulation for VR/AR, gaming, training simulations, and accessibility devices. SDK-compatible for custom stimulation patterns.
Frequently asked questions
What applications is ElecSil™ designed for?
ElecSil™ is used in wearable applications that require electrical stimulation, haptic feedback, or biosignal sensing. It can be applied to EMS, electrotactile haptics, and biometric data collection such as ECG and EMG across sports, medical and wellbeing, education and training, gaming, and workwear products. ElecSil™ has not been validated for EEG, but you are welcome to try the standard electrodes on hairless sites such as the forehead.
How do I choose the right ElecSil™ model for my application?
The right ElecSil™ model depends on your application, electrode area, connector preference, and integration method. Different ElecSil™ options are available for biosignal sensing, stimulation, and garment integration, so we recommend selecting the model based on your required size, skin contact condition, and product design.
Stable conductivity under stretch
ElecSil™ maintains electrical performance even when stretched by 20% — tested over 100 repeated cycles. This makes it ideal for wearables that move with the body, ensuring reliable signal capture in real-life use, from EMG wearables to rehabilitation gear.
Dry electrode vs. gel electrode
ElecSil™ uses dry electrode technology, meaning no conductive gel is required. This allows for faster setup, reusable application, and consistent signal quality over extended wear — making it ideal for daily-use wearables and long-duration monitoring.
Compatible bio-signal applications
ElecSil™ is designed for EMG (electromyography), ECG (electrocardiography), and other bio-signal monitoring applications. Its stretchable conductive fabric integrates directly into garments for seamless, comfortable data acquisition. ElecSil™ has not been validated for EEG (electroencephalography), but you are welcome to try the standard electrodes on this page on hairless sites such as the forehead.
Biocompatible dual-layer design
Made from medical-grade PDMS infused with conductive fillers, ElecSil™ includes a silver-copper top layer for conductivity and a carbon-black skin-contact layer that meets ISO 10993-5 and -10 standards. It's safe for long-term skin contact and designed to be gentle yet effective.
Washable & durable construction
ElecSil™ is built to last through repeated use. It's been tested for machine wash durability (with both wool and alkaline detergents) and remains functional with or without Velcro skin attachment. This means lower replacement rates and easier maintenance in daily-use scenarios.
Can ElecSil™ be customized in size, shape, or layout?
Yes. ElecSil™ can be customized in size, shape, and layout depending on your product design and application requirements. Customization can also be discussed based on electrode area, garment integration, and connection format.
To proceed, please share your desired size specifications, drawings (if available), and the estimated order quantity. Our team will review the details and provide a tailored quotation.
Does ElecSil™ support snap, magnetic, or custom connector options?
Yes. ElecSil™ samples are available with different attachment options including snap buttons, magnetic buttons, or no connector, depending on the model. For product development, we can also support you by discussing feasible integration options and recommending compatible cabling or connector solutions.
ElecSil™ is currently not sold as a ready-made kit with pre-assembled cables and connectors on our website, but an official ElecSil™ kit with integrated connectivity is planned for release by fall 2026.
R&D, prototyping & custom integration
WaveWear offers custom ElecSil™ integration services for R&D teams and product developers. Whether you need specific shapes, sizes, or electrode configurations, we can support your prototyping and production needs. Contact us at tech@wavecompany.net for collaboration inquiries.
How can I order samples and request technical information?
You can review basic technical specifications and purchase available ElecSil samples directly on this page. For more detailed technical data, volume-based pricing, or MOQ (Minimum Order Quantity) for bulk orders, please contact us.
How is ElecSil™ priced for volume production?
Indicative pricing (as of September 2026, subject to change): for mass production of ElecSil non-invasive skin electrodes, prices start from USD 6 per unit. This is our lowest reference price, based on the following conditions:
- 4 cm diameter round ElecSil A+B electrode
- 1,000 pcs production volume (MOQ)
- No snap buttons, leads, or additional connectors included
Larger or custom-shaped electrodes, connectors, lower volumes, or specific impedance requirements are quoted above this reference. Final pricing is confirmed in a formal quote. Please contact us.
What if I need shipping support or a custom order for my region?
If your destination country is not available at checkout, please contact us. We can ship using your FedEx/DHL account or arrange a manual shipment. Additionally, we offer customization for specific sizes or configurations. Share your requirements with us, and we will review the feasibility.
Safety & Advanced Materials Policy
Certain smart textile materials are subject to additional verification and may be cancelled/refunded under this policy.
Advanced Materials Use Policy (ElecSil & Smart Textile Materials)
1. Scope of this policy
This Advanced Materials Use Policy applies to ElecSil and other smart textile materials (the “Products”) supplied by Wave Company through the WaveWear website (“WaveWear”, “we”, “our”). It forms part of our Terms of Service and applies to all orders containing these Products.
2. Intended use
ElecSil and other smart textile materials sold by WaveWear are supplied strictly for legitimate research, prototyping, product development, and industrial or institutional use. They are not intended for human or animal ingestion, implantation, or any unapproved medical, diagnostic, or life‑support applications.
3. Eligible customers and verification
We primarily supply these Products to verified companies, research institutions, universities, laboratories, and professional creators. We may request additional information before fulfilling an order, including but not limited to: organisation name, organisation website, tax or business registration details, intended use, and a company email address for verification.
We may require the customer to reply from a verifiable company email address (e.g. name@company.com) or provide other reasonable documentation (such as a business card or institutional proof) to complete this verification process.
4. Right to refuse, hold, cancel and refund orders
Wave Company reserves the right, at its sole discretion, to refuse, hold, or cancel any order that appears inconsistent with safe and lawful use of our Products, including but not limited to:
- Orders placed by unverified individuals or entities.
- Orders for which the customer does not provide sufficient information for verification within the requested timeframe.
- Orders where the intended use is unclear, unsafe, or appears to conflict with this Policy or applicable laws and regulations.
In such cases, we may cancel the order and issue a refund of any payments received for the affected Products.
5. Customer responsibilities
The buyer is responsible for ensuring that their use of smart textile materials complies with all applicable laws, regulations, safety standards, and certification requirements in their country or region.
The buyer must implement appropriate protective measures, insulation, testing, and risk assessments when integrating smart textile materials into electrical systems, wearables, or medical devices, and must not rely solely on WaveWear’s marketing materials as a substitute for professional engineering, medical, or safety advice.
6. Timeframe for providing verification
Where additional information is requested for verification, the customer must provide the requested information within 3 days from the date of our request (or any other deadline explicitly stated in our communication). If the customer fails to provide sufficient information within this timeframe, or if we are unable to satisfactorily verify the information provided, we may cancel and refund the order in accordance with this Policy.
7. Changes to this policy
Wave Company may update or modify this Advanced Materials Use Policy from time to time. The version published on the WaveWear website at the time of order placement will apply to that order.

ElecSil™ Type 6 - Conductive E-textile
$39.99